Precautions for using anti-corrosion magnetic flap level gauge

Anhui Xinyuan Click:0 Release time:2025-07-25
Precautions for using anti-corrosion magnetic flap level gauge
1. For liquid level gauges that exceed a certain length (ordinary type>3 meters, anti-corrosion type>2 meters).
2. The installation position of the magnetic flap level gauge should avoid or be far away from the inlet and outlet of the material medium to avoid rapid changes in the local area of the material fluid, which may affect the accuracy of the level measurement;
3. When equipped with remote transmission instruments, the following measures should be taken:
4. The remote transmission supporting instruments should be tightly attached to the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited);
5. The sensing surface on the remote transmission supporting instrument should face and be closely attached to the main pipe;
6. When debugging, the upper inlet valve should be opened first, and then the lower valve should be slowly opened to allow the medium to enter the main pipe smoothly (during operation, the medium should avoid rapid impact on the float, causing the float to fluctuate dramatically and affecting the display accuracy). Observe whether the magnetic red and white balls flip normally, then close the lower inlet valve, open the drain valve, and let the liquid level in the main pipe decrease. Follow this method three times, if it is normal, it can be put into operation (except for corrosive and other special liquids);
7. According to the condition of the medium, the main tube of the magnetic flap level gauge should be cleaned irregularly to remove impurities;